Posted Date
Effective Date
Test Name
Hantavirus Antibodies, IgG & IgM
Update Type
New Tests
CPT Code
86790 x2
Order Code
TBD
NEW TEST
Hantavirus Antibodies, IgG & IgM
Order Code: pending
Fee Code: AA491 (CPT 86790 x2)
Reference Laboratory: Mayo HANGM
Mayo Clinic Laboratories will begin offering Hantavirus Antibodies, IgG & IgM, effective August 25, 2026. This test will replace Mayo test ID FHVGM (order code FHVGM) referred to Quest Diagnostics.
Collection Instructions: Collect specimen in an SST (preferred) or red top tube. Centrifuge, aliquot 0.6 mL (minimum 0.5 mL) of serum into a plastic vial, and refrigerate.
Reference Range: IgM: Negative, IgG: Negative.
- False-negative results may occur in patients that are tested either too soon following infection or are significantly immunocompromised.
- False-positive results may occur in patients with recent cytomegalovirus infection.
- This assay detects IgM and IgG antibodies against antigens from the Sin Nombre and Andes Hantavirus strains; however, it will not differentiate between the two strains. It is unknown if this assay will detect antibodies to other Hantavirus strains.
- Results must be interpreted alongside epidemiological exposure history and clinical presentation, and diagnosis should not be made solely on serologic results from this assay.