Test Overview
Test Methodology

Indirect Immunofluorescence

Test Usage

Detection of circulating anti-neutrophil antibodies in suspected cases of autoimmune neutropenia. The work-up of individuals having febrile, nonhemolytic transfusion reactions.

Reference Range *

Negative (reported as positive or negative).

Test Limitations

No distinction can be made between autoantibodies and alloantibodies. This test is not useful for diagnosis of neutropenia caused by marrow suppression by drugs or tumors.

Test Details
Days Set Up
Tuesday, Wednesday, Friday
Analytic Time

7 - 16 days

Soft Order Code
LAGG
MiChart Code
Granulocyte Ab S (Sendout)
Synonyms
  • NEUAB
  • Leukocyte Antibody
  • Anti-Leukocyte Antibody
  • Granulocyte Antiboides, Serum
  • Anti-Neutrophil Antibody
  • Anti-PMN Antibody
  • Neutrophil Antibodies
  • Anti-Granulocyte Antibody
  • LAGG
Laboratory
Sendout
Reference Laboratory
Mayo LAGGT (8976)
Section
Special Testing
Specimen Requirements
Collection Instructions

Collect specimen in a red top tube; do not use SST tube. Centrifuge, aliquot serum into a plastic vial and refrigerate or freeze.

Rejection Criteria
SST tube not acceptable.
Yellow Top Tube
Red Top Tube
Normal Volume
1.5 mL serum
Minimum Volume
0.3 mL serum
Additional Information

Test sent to Mayo Medical Laboratories. University of Michigan registered patient specimens sent to American Red Cross, North Central Blood Services, Neutrophil Serology Laboratory.