Test Overview
Test Methodology

Automated Nanoliter Scale Immunoassay

Test Usage

Detection of anti-CV2 autoantibodies using recombinant human antigens.

Reference Range *

Serum: <1:100
CSF: <1:1

* Reference ranges may change over time. Please refer to the original patient report when evaluating results.

Test Details
Analytic Time

4 - 7 days

Soft Order Code
SO
Synonyms
  • Recombx CV2 Antibody Test
  • CV2 Paraneoplastic Syndrome
Laboratory
Sendout
Reference Laboratory
Athena Diagnostics 4681
Section
Special Testing
Specimen Requirements
Collection Instructions

Collect specimen in a red top or SST tube. Centrifuge, aliquot serum into a plastic vial and refrigerate.
CSF is also acceptable

Normal Volume
2 mL serum or CSF
Minimum Volume
0.5 mL
Additional Information

Test sent to Athena Diagnostics.

Billing
CPT Code
84182