Update Type: New Tests
Test Updated: 02/04/2026
Test Overview
Test Methodology
Conventional PCR followed by genotypic sequencing.
Reference Range *
Mutations in the UL97 and UL54 genes will be reported as Resistant/None Detected.
* Reference ranges may change over time. Please refer to the original patient report when evaluating results.
Test Details
Days Set Up
Monday - Saturday
Soft Order Code
VCMR3
Synonyms
Laboratory
Sendout
Reference Laboratory
Eurofins Viracor #5600
Section
Special Testing
Specimen Requirements
Collection Instructions
Collect 4-5 mL whole blood in EDTA, ACD or PPT tube. Spin and aliquot onto a screw capped plastic tube. Send to Specimen Processing room temp. (can be frozen for storage longer than 7 days)
Special Handling
Store room temp if will arrive at Viracor within 7 days. Ship frozen if it will be longer than that.
Normal Volume
2 mL plasma
Minimum Volume
0.2 mL plasma
Storage Temperature
Ambient or frozen
Additional Information
Test performed by Eurofins Viracor
Billing
CPT Code
87910 x2
Fee Code
AB228 x2
NY State Approved