Test Overview
Test Methodology
Chemiluminescent Immunoassay (CLIA)
Test Usage
To aid as a marker in the diagnosis of testicular tumors
Reference Range *
< 8 ng/mL (Males and Non-pregnant Females aged >=2 years)
* Reference ranges may change over time. Please refer to the original patient report when evaluating results.
Test Details
Days Set Up
Daily, 24 hours
Analytic Time
2 hours
Soft Order Code
AFP
MiChart Code
AFP (Alpha Fetoprotein), Tumor Marker
Synonyms
- AFP Tumor Marker
- AFP, Tumor Marker
- AFP
- ALPHA FETOPROTEIN-TUMOR MARKER
Laboratory
Chemical Pathology
Section
Automation
Specimen Requirements
Collection Instructions
Collect specimen in an SST or red top tube. Refrigerate and send intact specimen within 8 hours of collection. Alternatively, centrifuge, aliquot serum into a plastic vial and refrigerate up to 48 hours or freeze for longer storage.
Alternate Specimen
Red Top Tube
Normal Volume
1 mL serum
Minimum Volume
0.25 mL serum
Additional Information
Tested by a chemiluminescent immunoassay manufactured by Siemens Healthineers, performed on Atellica IM system. Results determined from different manufacturers and/or methods may not be comparable.
Billing
CPT Code
82105
Fee Code
22170
LOINC
1834-1