Test Name Quinidine, Serum
Posted Date
Effective Date
Update Type Test Discontinued
CPT Code 80194
Order Code MQUIN

TEST OBSOLETE

 

Quinidine, Serum

 

Order Code:                  MQUIN

Fee Code:                     AA351 (CPT 80194)

Reference Lab:             Mayo QUIN

 

Due to limited utilization, Mayo Clinic Laboratories will make Quinidine, Serum (test code QUIN) obsolete effective November 6, 2025. The recommended alternative will be forwarded to LabCorp (test: Quinidine, Serum or Plasma - 007831). 

Collection Instructions: Collect a red-top or green-top (heparin) tube. Do not use a gel-barrier tube. Transfer separated serum or plasma into a plastic transport tube. Specimen is stable at room temperature, refrigerated, and frozen for 14 days. 

Peak: quinidine sulfate: 1.5 hours after dose, quinidine gluconate: 4 hours after dose.

Trough: immediately prior to next dose.

After change in dose: one to two days.

 

Reference Range: Therapeutic: 2.0-5.0 μg/mL