Days Set Up
Daily, 24 hrs
Analytic Time

2 hours

Soft Order Code
TOBR/TOBPK/TOBTR

Test Updated:

Synonyms

Nebcin
Nebcin
Nebcin
TOB R
TOB PK
TOB TR
TOBRAMYCIN, RANDOM
TOBRAMYCIN, PEAK
TOBRAMYCIN, TROUGH

Looking to order a test?

We’ve provided helpful links to make ordering easy.

Find a Requisition

All specimens should be accompanied by a requisition.

Submitting Specimens

Learn about how to properly label and where to ship specimens.

Order Kits and Supplies

MLabs provides all the supplies necessary for the collection of specimens.

Test FAQ

Visit our provider FAQ and learn about common questions to ordering tests.

Test Overview

Test Methodology

Homogeneous Enzyme Immunoassay

Test Usage

Monitor therapeutic drug level

Reference Range

Therapeutic: Peak: 5 - 10 mcg/mL; Trough: < 2 mcg/mL.
Critical: Peak/Random values: >10.5 mcg/mL; Trough values: >2.6 mcg/mL.

* Reference ranges may change over time. Please refer to the original patient report when evaluating results.

Specimen Requirements

Collection Onsite

Collect blood in an SST tube. Mark clearly whether specimen is Peak, Trough, or Random collection.

Collection Offsite

Collect blood in an SST tube. Centrifuge, aliquot serum into a plastic vial and refrigerate. For maximum clinical significance, usual sampling times are Peak: 0.5 to 1 hour after the end of a 30 minute I.V. infusion (one hour following I.M. administration) or Trough: immediately before next dose is given. Indicate whether specimen is Peak, Trough, or Random level.

Yellow Top Tube
Normal Volume
0.5 mL serum
Minimum Volume
0.25 mL serum

Billing Information

CPT Code
80200
Pro Fee Code
 
LOINC
Trough 4059-2; Peak 4057-6; Random 35670-9

Have More Questions?

Explore our helpful billing resources:

Our High Standard

Quality that sets us apart

As the reference laboratory division of Michigan Medicine's Department of Pathology, MLabs shares the institution's commitment to applying established quality principles to clinical laboratory testing. Like other large organizations in complex, consequential fields, we rely on an established approach to monitor quality throughout the testing process.