Days Set Up
Daily (Monday - Friday only)
Analytic Time

1 hour

MiChart Code
Thrombin Time
Soft Order Code
TCTD

Test Updated:

Synonyms

Thrombin Time, Diagnostic
TTD CONT
TTD SEC
DIGNOSTIC THROMBIN TIME CONT
THROMBIN TIME DX, SECONDS

Looking to order a test?

We’ve provided helpful links to make ordering easy.

Find a Requisition

All specimens should be accompanied by a requisition.

Submitting Specimens

Learn about how to properly label and where to ship specimens.

Order Kits and Supplies

MLabs provides all the supplies necessary for the collection of specimens.

Test FAQ

Visit our provider FAQ and learn about common questions to ordering tests.

Test Overview

Test Methodology

Clot determination with human thrombin.

Test Usage

Detection of low or dysfunctional fibrinogen and fibrinolytic degradation products.

Reference Range

< 21 seconds

* Reference ranges may change over time. Please refer to the original patient report when evaluating results.

Specimen Requirements

Collection Onsite

Collect specimen in a blue top (citrate 3.2%) tube. Mix by inversion. Specimen should arrive at lab within 3 hours of collection; transport at room temperature. Collection of the blood through lines that have been previously flushed with heparin should be avoided. If the blood must be drawn through a VAD (vascular access device), the line should be flushed with 5 mL of saline and the first 5 mL of blood or six dead space volumes of the VAD discarded.

Collection Offsite

Collect specimen in a blue top (citrate 3.2%) tube. Mix by inversion. Specimen should arrive at lab within 3 hours of collection; transport at room temperature. Alternatively, centrifuge, aliquot plasma into a plastic vial, and freeze the specimen within 4 hours of collection. Transport frozen specimen on dry ice. Collection of the blood through lines that have been previously flushed with heparin should be avoided. If the blood must be drawn through a VAD (vascular access device), the line should be flushed with 5 mL of saline and the first 5 mL of blood or six dead space volumes of the VAD discarded.

Blue Top Tube
Normal Volume
Full 2.7mL tube or 1mL plasma aliquot
Minimum Volume
Full 1.8mL tube or 1mL plasma aliquot

Billing Information

CPT Code
85670
Pro Fee Code
 
LOINC
 

Have More Questions?

Explore our helpful billing resources:

Our High Standard

Quality that sets us apart

As the reference laboratory division of Michigan Medicine's Department of Pathology, MLabs shares the institution's commitment to applying established quality principles to clinical laboratory testing. Like other large organizations in complex, consequential fields, we rely on an established approach to monitor quality throughout the testing process.