Analytic Time

4 - 7 days

MiChart Code
Prostate Cancer Antigen 3 (PCA3)
Soft Order Code
PCA3

Test Updated:

Synonyms

PCA3
PCA3 (Prostate Cancer Antigen 3)
Prostate Cancer Gene 3
Differential Display Code 3 (DD3)
PCA-3
PCA3S

Looking to order a test?

We’ve provided helpful links to make ordering easy.

Find a Requisition

All specimens should be accompanied by a requisition.

Submitting Specimens

Learn about how to properly label and where to ship specimens.

Order Kits and Supplies

MLabs provides all the supplies necessary for the collection of specimens.

Test FAQ

Visit our provider FAQ and learn about common questions to ordering tests.

Test Overview

Test Methodology

Transcription Mediated Amplification (TMA) and Hybrid Protection Assay (HPA)

Test Usage

Adjunct to serum PSA for risk stratification of patients undergoing repeat prostate biopsy. The PCA3 test is a molecular assay that detects the mRNA expression of the DD3 gene expressed in prostate cells. In recent studies it was shown to have a specificity of 78% and a sensitivity of 57% in cancer vs. non-cancer.

Reference Range

The PCA3 score is reported as a quantitative PCA3/PSA mRNA ratio x 1000 to normalize PCA3 to the amount of prostate RNA present in the urine sample. Cases with insufficient PSA mRNA are considered inconclusive. A score equal to or greater than 25 is considered positive. A positive result is associated with increased likelihood of a positive biopsy for cancer.

* Reference ranges may change over time. Please refer to the original patient report when evaluating results.

Specimen Requirements

Collection Onsite

Perform an attentive DRE immediately prior to specimen collection (the specimen should be collected within approximately 1 hour of DRE). Instruct patient to collect the FIRST 20 - 30 mL of voided urine following the DRE. Process the specimen as follows within 4 hours of collection (if specimen cannot be processed within 15 minutes, store refrigerated or on ice and process within 4 hours): 1) Invert specimen cup 5 times to re-suspend cells. 2) Add 2.5 mL of urine to each of two GEN-PROBE PROGENSA PCA3 Urine Specimen Transport Tubes. Do NOT puncture the foil seal on the cap of the Transport Tube. The specimen volume must fall between the two black fill lines on the Transport Tube. 3) Tightly re-cap each Urine Transport Tube and gently invert 5 times to mix; do not shake or vortex. The specimen is now a "processed" urine specimen. Refrigerate.

Collection Offsite

Perform an attentive DRE immediately prior to specimen collection (the specimen should be collected within approximately 1 hour of DRE). Instruct patient to collect the FIRST 20 - 30 mL of voided urine following the DRE. Process the specimen as follows within 4 hours of collection (if specimen cannot be processed within 15 minutes, store refrigerated or on ice and process within 4 hours): 1) Invert specimen cup 5 times to re-suspend cells. 2) Add 2.5 mL of urine to each of two GEN-PROBE PROGENSA PCA3 Urine Specimen Transport Tubes. Do NOT puncture the foil seal on the cap of the Transport Tube. The specimen volume must fall between the two black fill lines on the Transport Tube. 3) Tightly re-cap each Urine Transport Tube and gently invert 5 times to mix; do not shake or vortex. The specimen is now a "processed" urine specimen. Refrigerate. Refrigerated specimens must be received by MLabs within 5 days of collection. For longer storage, freeze specimen at -20 degrees C and ship specimen on dry ice. Frozen specimens are stable for 90 days at -20 degrees C. Include serum PSA result and patient history with the specimen.
Obtaining informed consent from the patient prior to genetic testing is strongly recommended. If desired, a UMHS Request and Consent for Genetic Testing form can be obtained by contacting the MLabs Client Services Center at 800-862-7284 or online at https://mlabs.umich.edu/sites/default/files/2020-01/file/pci-mmgl_infor….

Red Top Tube
Normal Volume
30 mL urine
Minimum Volume
5 mL urine

Billing Information

CPT Code
81313
Pro Fee Code
 
LOINC
 

Have More Questions?

Explore our helpful billing resources:

Our High Standard

Quality that sets us apart

As the reference laboratory division of Michigan Medicine's Department of Pathology, MLabs shares the institution's commitment to applying established quality principles to clinical laboratory testing. Like other large organizations in complex, consequential fields, we rely on an established approach to monitor quality throughout the testing process.