Days Set Up
Monday - Friday, 8:00am - 4:00pm
Analytic Time
 
MiChart Code
Cytogenetics, CLL FISH Panel
Soft Order Code
CGCLL

Test Updated:

Synonyms

Locus Anomalies, CLL, FISH
Chronic Lymphocytic Leukemia (CLL), FISH panel
CLL FISH
FCLL
FISH for Chronic Lymphocytic Leukemia (CLL)
CGCLL
CGLABEL
GENERIC CYTOGENETICS TEST
FISH del(13q) Probe
IGH/CCND1, FISH Probe
D13S319, FISH Probe
ATM, FISH Probe
TP53, FISH Probe
D12Z3, FISH Probe
FISH del(17p) Probe
FISH del(11q) Probe
FISH +12 Probe
FISH t(11;14)(q13;q32) Probe

Looking to order a test?

We’ve provided helpful links to make ordering easy.

Find a Requisition

All specimens should be accompanied by a requisition.

Submitting Specimens

Learn about how to properly label and where to ship specimens.

Order Kits and Supplies

MLabs provides all the supplies necessary for the collection of specimens.

Test FAQ

Visit our provider FAQ and learn about common questions to ordering tests.

Test Overview

Test Methodology

Interphase Fluorescence In Situ Hybridization (FISH)

Test Usage

The CLL FISH panel is used to ascertain common recurrent genetic abnormalities that have known prognostic significance in CLL when detected by interphase FISH analysis. Use at the time of diagnosis of CLL for prognostic information and to differentiate from mantle cell lymphoma associated with the t(11;14), and, at progression or relapse to detect clonal evolution. The panel includes tests for the following chromosome abnormalities using probes for the specific gene locus (in italics); deletion of 13q at 13q14.3, del(13q), (D13S319); trisomy 12, +12, (D12Z3); deletion of 11q at 11q22.3, del(11q), (ATM); deletion of 17p at 17p13.1, del(17p), (TP53); and translocation of 11q13 and 14q32, t(11;14)(q13;q32), (IGH/CCND1). Note: while other hematologic malignancies frequently carry similar genetic abnormalities, the prognostic significance may differ significantly from that found for CLL. Also, this test cannot discern for all loci tested whether the clonal abnormalities detected are present in the same clonal population or whether independent clonal proliferations are present. Thus, if myelodysplastic syndrome is suspected a bone marrow sample should be sent for standard cytogenetic analysis.

Reference Range

Interpretive report provided.

* Reference ranges may change over time. Please refer to the original patient report when evaluating results.

Specimen Requirements

Collection Onsite

Collect specimen in a sterile syringe rinsed with sodium heparin or a green top Vacutainer® (sodium heparin) tube. Invert several times to prevent clotting. Send at room temperature as soon as possible. Do not allow specimen to overheat or freeze. Please complete a MiChart test request and submit it with the specimen. A Cytogenetics Laboratory Requisition is available online at: http://www.pathology.med.umich.edu/handbook/Tables/UM_REQ_CYTOGENETICS…. CLL FISH panel testing may be performed as a "stand alone" test or included with Chromosome Analysis, Bone Marrow testing.

Collection Offsite

Specimen transport should be arranged so that the specimen is received by MLabs the same day it is collected. Call for a STAT courier if necessary. Collect specimen in a green top (sodium heparin) tube. Invert the tube several times to prevent clotting. Send at room temperature as soon as possible. Do not allow specimen to overheat or freeze. Clotted samples or those that are greater than 24 hours old are suboptimal. CLL FISH panel testing may be performed as a "stand alone" test or included with Chromosome Analysis, Bone Marrow testing.

Normal Volume
5 mL whole blood (with >10% involvement) or 2 mL bone marrow
Minimum Volume
2 mL whole blood (with >10% involvement) or 1 mL bone marrow

Billing Information

CPT Code
88237, 88275 x3, 88271
Pro Fee Code
 
LOINC
 

Have More Questions?

Explore our helpful billing resources:

Our High Standard

Quality that sets us apart

As the reference laboratory division of Michigan Medicine's Department of Pathology, MLabs shares the institution's commitment to applying established quality principles to clinical laboratory testing. Like other large organizations in complex, consequential fields, we rely on an established approach to monitor quality throughout the testing process.